Products

Order Solar Power Products Online

Zephyr Power Vent

Zephyr Power Vent battery box vent

Lead-acid batteries produce hydrogen gas when charging, but leaving a battery box lid open to vent gas in cold climates can reduce battery capacity. Proper venting and thermal management is especially important when battery boxes are placed in basements, garages and sheds. As heat rises in the structure, a low pressure area forms around the battery box and pushes cool air into the box which forces gases out and into the structure. The Power Vent controls battery box venting, removing hydrogen gas while reducing cold air infiltration into the box. The Power Vent contains a gravity operated damper that normally stays closed. When connected to a voltage-controlled relay, the fan operates only when the batteries are being charged and blows gas vapors out. Designed for battery banks under 2,200 Ah and charge rates under 125 A. The fan can be operated from the auxiliary relay on high-end charge controllers or by a voltage controlled switch (see Converters and Controls). The 12 and 24 VDC units use 3 W and push air at 6 CFM. They are 4" in diameter and 7.25" long with a 2" PVC pipe socket on the inlet and outlet. The 48 VDC unit uses 6 W and pushes 8 CFM, it measures 4" in diameter and is 10" long, with a 3" PVC pipe socket on the inlet and outlet.


Description Item code

Power vent 12V

085-08205

Power vent 24V

085-08207

Power vent 48V

085-08209

Order Solar Power Products Online