The Xantrex GT100 and GT250 grid-tie inverters feature integrated design with an isolation transformer and have a CEC efficiency of 96%. The sealed design requires no filters or external air to cool sensitive components and allows for zero clearance on the back and sides. A removable air outlet allows the inverter to be vented easily. Wiring access points are on the bottom, sides and back of the inverter. AC and DC disconnects are included. Powder coated steel enclosures offer maximum corrosion resistance. Negative- or positive-ground system configuration is possible. Optional fused subarray combiners with 100A, 150A or 200A circuits are integrated with the inverter enclosure (must be factory installed and ordered with inverter). Optional RS-485/MODBUS or Ethernet communications interface kit is available for monitoring. All GT Series Inverters are backed by a standard 5-year warranty with 10- or 15-year optional extended warranties available. Optional uptime guarantee and preventative maintenance programs are available.
The GT500 offers the same features as the GT100/GT250 inverters, but the GT500 offers 500kW of output and is supplied with an external transformer. The GT500 MVX is for direct connection to a MV transformer (not included).
Optional subarray combiners are available for all GT inverters 100kW and larger. Subarray combiners are integrated into the inverter and must be ordered with the inverter at time of inverter order
Optional extended warranties, preventive maintenance, and uptime guarantees are available for 100kW and larger inverters. Schneider also has an on-site commissioning contract available. Call AEE for pricing on these options.
|
GT Commercial Inverter Options |
||||
|
Fits Inverter model |
Description |
Number of fused inputs |
Fuse size |
Item code |
|
GT30 |
30 KVA Autotransformer 208V to 480V for one GT30 |
030-02083 |
||
|
75 KVA Autotransformer 208V to 480V for two GT30's |
030-02084 |
|||
|
112.5 KVA Autotransformer 208V to 480V for three GT30's |
030-02085 |
|||
|
GT100 |
Sub-array input fusing |
3 |
200A |
030-02063 |
|
4 |
150A |
030-02064 |
||
|
6 |
100A |
030-02065 |
||
|
GT250 |
Sub-array combiner |
16 |
150A |
030-02069 |
|
Sub-array combiner with String Monitoring |
Call |
|||
|
Sub-array combiner |
30 |
100A |
030-02070 |
|
|
Sub-array combiner with String Monitoring |
Call |
|||
|
GT500 |
Sub-array combiner |
16 |
200A |
030-02075 |
|
Sub-array combiner with String Monitoring |
030-02076 |
|||
|
Subarray combiner |
20 |
150A |
030-02077 |
|
|
Sub-array combiner with String Monitoring |
030-02078 |
|||
|
Other fuse combinations for GT250 and GT500 with and without String Monitoring |
Call |
|||