The FLEXware PV8 and PV12 accommodate overcurrent protection requirements for off-grid and grid-connected applications. The DIN rail can be fitted with 150 VDC circuit breakers for low-voltage PV arrays or 600 VDC fuse holders for grid-tie arrays. Rated NEMA 3R rainproof, the powder-coated aluminum chassis can be mounted on a wall, a sloped roof, or a pole. Dual output lugs allow connection for up to #2/0 AWG wire. An easily removable flame-retardant polycarbonate deadfront panel prevents accidental contact with live terminals. FLEXware PV8 has 1 output circuit and FLEXware PV12 can be configured to have 1 or 2 output circuits. Negative and ground terminal busbars are included. The 2 output circuits can be used for fuses in both the negative and positive legs for up to 4 strings into a transformerless inverters. Limited to 15 A breakers or fuses. Listed to UL 1741.
| OutBack model | # of breakers | # of fuse holders | Dimensions (inches) | Weight (lbs) | Item code |
|
FWPV8 |
8 |
6 |
15.2 x 12.7 x 3.9 |
4.4 |
053-03012 |
|
FWPV12 |
12 |
8 |
15.2 x 9.2 x 3.9 |
5.9 |
053-03014 |