OutBack G-Series inverter/chargers are the grid-interactive versions in OutBack's FX inverter line. Available in either sealed (GTFX) or vented (GVFX) models, these inverters allow you to sell solar, wind, and/or hydro power back to the utility grid. If the utility power goes down, the inverter will automatically isolate themselves from the grid and use a battery bank and/or your renewable energy source(s) to power your critical loads. The inverter can be set up so that either utility power or your renewable sources (PV array, wind turbine, etc.) can be used after an outage to recharge the battery bank. AC power is seamlessly switched between utility and battery power through the inverter's built-in 60A transfer switch. With the OutBack grid-interactive system, backup AC power is made available 24 hours a day in the event of a utility outage, providing reliable power and peace of mind. At night, the inverter's automatic power save mode ensures that energy is not wasted by needlessly charging your batteries from the utility grid. With a healthy battery bank, daily energy rodction efficiency is very close to that of typical grid-intertie systems without backup. Up to two G-Series inverters can be "stacked" for 120/240V output. They come with a standard 5-year warranty with an optional 10-year extended warranty available where required by state incentive prorams and are Listed to UL 1741 for U.S. and Canada.
OutBack Inverters for Latin AmericaOutBack GTFX-LA and GVFX-LA grid-tie inverters are designed to be used in Mexico and other parts of Latin America where the grid power is uneven. They have 127VAC/60Hz output, and have widened grid input voltage and frequency ranges to work better with less regulated utility grids. As with the other OutBack inverters, the "T" models have a sealed chassis and an external cooling fan, and the "V" models have a fan-cooled, vented chassis. NOTE: OutBack LA inverters are NOT Listed to UL 1741 and NOT intended for use in the U.S. or Canada.

The OutBack GFX International Series grid-tie inverters are designed for use in countries that have utility grids that frequently experience power instability such as surges, spikes, or brownouts; or where standard inverters have trouble syncing to the utility grid. The GFX International Series grid-reconnect timers have been shortened to reduce overall sell-back downtime and improve system functionality. Otherwise, the International Series inverters are similar to other OutBack GFX models, but without an exterior cooling fan. The built-in transfer relay automatically disconnects your loads from the utility grid and powers them from the inverter in the event of an outage, allowing you to continue using your solar and battery back-up power. They have a sealed chassis that can operate in the harshest environmental conditions such as high humidity and corrosive salt air. Models are available for areas with nominal AC voltages of 230 VAC/50Hz, and for areas with 120 VAC/60Hz. DC cover included. 5-year warranty.
NOTE: OutBack GFX International Series inverters are NOT ETL Listed to UL 1741. NOT intended for use in the U.S. or Canada.
|
Model |
Continuous watts |
Battery |
AC out volts/ |
No load |
Charger |
AC surge |
Weight |
Item code |
|
US Models - can be connected in series 120/240 |
||||||||
|
Ventilated Cooled Inverters |
||||||||
|
GVFX3524 |
3500 |
24VDC |
120V/60Hz |
20 W |
85 A |
6000 W |
61 |
030-04032 |
|
GVFX3648 |
3600 |
48VDC |
120V/60Hz |
23 W |
45 A |
6000 W |
61 |
030-04036 |
|
Sealed/Turbo Cooled Inverters |
||||||||
|
GTFX2524 |
2500 |
24VDC |
120V/60Hz |
20 W |
55 A |
6000 W |
63 |
030-04025 |
|
GTFX3048 |
3000 |
48VDC |
120V/60Hz |
23 W |
35 A |
6000 W |
63 |
030-04030 |
|
Latin America Models |
||||||||
|
Ventilated Cooled Inverters |
||||||||
|
GVFX3524LA |
3500 |
24 VDC |
127V/60Hz |
20 W |
85 A |
6000 W |
61 |
030-04022 |
|
GVFX3648LA |
3600 |
48VDC |
127V/60Hz |
23 W |
45 A |
6000 W |
61 |
030-04023 |
|
Sealed/Turbo Cooled Inverters |
||||||||
|
GTFX2524LA |
2500 |
24VDC |
127V/60Hz |
20 W |
55 A |
6000 W |
63 |
030-04020 |
|
GTFX3048LA |
3000 |
48VDC |
127V/60Hz |
23 W |
35 A |
6000 W |
63 |
030-04021 |
|
International Series |
||||||||
|
Ventilated Cooled Inverters |
||||||||
|
GVFX2612E |
2600 |
12VDC |
230V/50Hz |
20 W |
125 A |
4600 W |
61 |
030-04053 |
|
GVFX3024E |
3000 |
24VDC |
20 W |
80 A |
5750 W |
030-04055 |
||
|
GVFX3048E |
3000 |
48VDC |
23 W |
40 A |
5750 W |
030-04057 |
||
|
Sealed/Turbo Cooled Inverters |
||||||||
|
GTFX2012E |
2000 |
12VDC |
230V/50Hz |
20 W |
100 A |
4600 W |
62 |
030-04052 |
|
GTFX2024E |
2000 |
24VDC |
20 W |
50 A |
5750 W |
030-04054 |
||
|
GTFX2348E |
2300 |
48VDC |
23 W |
30 A |
5750 W |
030-04056 |
||
|
Sealed Inverters |
||||||||
|
GFX1312 |
1300 |
12VDC |
120V/60Hz |
18 W |
70 A |
4600 W |
50 |
030-04013 |
|
GFX1424 |
1400 |
24VDC |
40 A |
030-04014 |
||||
|
GFX1548 |
1500 |
48VDC |
20 A |
030-04015 |
||||
|
GFX1312E |
1300 |
12VDC |
230V/50Hz |
18 W |
70 A |
4600 W |
50 |
030-04016 |
|
GFX1424E |
1400 |
24VDC |
40 A |
030-04017 |
||||
|
GFX1448E |
1400 |
48VDC |
20 A |
030-04018 |
||||