Products

Order Solar Power Products Online

FLEXware 500, 1000 and components

OutBack FLEXware

FLEXware 250


The FLEXware 250 offers a low-cost solution for single inverter installations where space and budget are primary concern. Use one FLEXware 250 on each end of the inverter, one for DC and one for AC. THere is space for a single charge controller and single pole GFDI. Use panel mount breakers (see Electrical DIstribution) for both DC and AC circuits, and one 175 A or 250 A breaker for the main inverter breaker.

FLEXware 500 and 1000


The FLEXware 500 supports up to two inverter/chargers and two charge controllers in an attractive, versatile and code-compliant package for installations where more power is needed. The FLEXware 1000 accommodates up to four inverter/chargers and four charge controllers. Multiple power panels can be used for systems up to 36 kW. Both the FLEXware 500 and 1000 systems provide ample locations for AC and DC breakers, DC-current shunts, an autotransformer and other items required in higher kW systems. The FLEXware MP mounting plate is used with with both FLEXware 500 and FLEXware 1000 enclosures. Use two mounting plates for the FW1000. The picture here shows the FLEXware 1000 AC and DC boxers with 4 inverters and 4 MX60 charge controllers. Use 3/4" panel mount breakers for DC circuits up to 100 A and 1" or 1 1/2" panel mount breakers (see Electrical Distribution) for 125, 175, or 250 A inverter breakers.

FLEXware Options


When adding charge controllers, additional inverters or circuit breakers, these components may be necessary.

FLEXware Integration Hardware FW250, FW500, and FW1000

Model

FLEXware 250 Power System Box and IOB Kits

Inverters

Item code

FW250

FLEXware 250 enclosure with TBB-ground, for one inverter (one for DC and one for AC) and one charge control

1

030-04205

FW-IOBS-120VAC

IOB kit includes three 60 A 120 VAC breakers and AC breaker bypass slide plate

030-04230

FW-IOBS-230VAC

IOB kit includes three 30 A 230 VAC breakers and breaker bypass slide plate - export

030-04233

FLEXware Mounting Plate

FW-MP

FLEXware Mounting plate for FLEXware 500 and 1000 enclosures (2 required for FW-1000 systems)

2

030-04260

FLEXware 500 Power System Box and IOB Kits

FW500-AC

FLEXware 500 enclosure with TBB-ground, DIN rail for AC breakers

1-2

030-04215

FW500-DC

FLEXware 500 enclosure with DC breaker bracket, TBB, BBUS, 500A shunt

030-04212

FW-IOB-D-120/240VAC

IOB kit includes six 60A 120VAC breakers and AC breaker bypass slide plate, busbars, wire

030-04237

FW-IOBD-120VAC

IOB kit includes six 60A 120VAC breakers and AC breaker bypass slide plate, busbars, wire

030-04240

FW-IOBD-230VAC

IOB kit includes six 30A 230VAC breakers and breaker bypass slide plate, TBB, wire - export

030-04243

FLEXware 1000 Power System Boxes and IOB Kits

FW1000-AC

FLEXware 1000 Enclosure with TBB-ground, DIN Rail for AC breakers

up to 4

030-04223

FW1000-DC

FLEXware 1000 Enclosure with DC Breaker bracket, TBB, 2 SBUS, BBUS, 500 A Shunt

up to 4

030-04221

FW-IOBQ-120/240VAC

IOB kit includes twelve 60A 120VAC breakers and AC breaker bypass slide plate, busbars, wire

4

030-04247

FW-IOBQ-230/AC

IOB kit includes twelve 30A 230VAC breakers and bypass slide plate, TBB, wire - EXPORT ONLY

030-04251

FW-IOBT-120/208VAC

IOB kit includes nine 60 A 120 VAC breakers and AC breaker bypass slide plate, busbars, wire

3

030-04253

FW-IOBT-230/400VAC

IOB kit includes nine 30A 230VAC breakers and bypass slide plate, TBB, wire - EXPORT ONLY

030-04255


Model

FLEXware options

Item code

FW-X240¹

4kVA 120/240VAC autotransformer -w/ 25A 2-pole breaker for mounting inside FLEXware 500 and 1000 AC enclosures

030-04270

OBR-16-30 VDC250 VAC-DIN

Relay 16 A maximum 30 VDC/250 VAC rated DIN rail mount

030-04193

PNL-GFDI-80

PV ground fault detector interrupter, 150 VDC, 80 A, 1 pole, panel mount

030-04324

PNL-GFDI-80D

PV ground fault detector interrupter, 150 VDC, 80 A, 2 pole, panel mount

030-04323

PNL-GFDI-80Q

PV ground fault detector interrupter, 150 VDC, 80 A, 4 pole, panel mount

030-04325

FW-SHUNT250

500 A 50 mv current shunt for top of vented inverter under top cover, with busbar to connect to negative post

030-04275

FW-SHUNT500

500 A 50 mv current shunt for FW500 and FW1000 includes terminal bus bar with white insulator

030-04277

TBB-GROUND

Ground/neutral terminal busbar with mounting screws (no insulators).

030-04356

TBB-WHITE

Bus bars with white insulators for grounded conductors (usually negative or neutral)

030-04354

TBB-BLACK

Bus bar with black insulators

030-04353

TBB-RED

Bus bar with red insulators

030-04355

TBB-BLUE

Bus bar with blue insulators (for 3-phase and export versions)

030-04359

TBB-BROWN

Bus bar with brown insulators (for export versions)

030-04352

FW-BBUS

FLEXware Breaker Bus connector two 175-250A, three 100-125A, four 1-80A DC breakers or three 500A DC shunts

030-04280

FW-SBUS

FLEXware shunt bus connector allows up to four high current cable connections on same side of DC shunt

030-04284

FW-CCB

FM charge controller mounting bracket for one side mounted on FW500 or FW1000 DC enclosures - with hardware

030-04263

FW-CCB2

FM charge controller mounting bracket for two side mounted on FW500 or FW1000 DC enclosures – with hardware

030-04265

FW-CCB2-T

FM charge controller mounting bracket for two top mounted on FW500 or FW1000 DC enclosures – with hardware

030-04267

FW-MB1

Mate mounting bracket for the side of a Flexware enclosure

030-04182

FW-MB2

Mate2 mounting bracket for the side of a Flexware enclosure

030-04183

FW-MB3

Mate3 mounting bracket for the side of a Flexware enclosure

030-04175

FW-MB3-F

Mate3 flat mounting for flush mounting

030-04176

FW-MB3-S

Mate3 surface mounting bracket

030-04177

¹The FW-X240 Autotransformer cannot be used for stacking with a grid-interactive FX system. However, the FW-X240 can be used to step-up the AC output of a single grid-interactive FX system from 120VAC to 240VAC.

Order Solar Power Products Online